Control system
- Wireless remote controller is standard
- Auto reset, operation mode control; with room sensor & coil sensor
- Daily timer or weekly timer
- Auto-diagnose, protections and error code display; jumpers configurations on electronic board
Design features
Suitable for hot/chilled water system, ceiling installation
Unit body
Made of galvanized steel, with pre-formed expanded polystyrene air passages suitable shaped to allow passage of air, thickness enough for thermal and acoustical insulation.
Panel assembly
Aesthetic panel design, in ABS material with synthetic washable and removal air filter, auto-swing.
Plastic wheel-quite running
One-time injection forming, no welding between the fan blades and inlet cone/end plate, it makes the wheel good balancing; an anti-vibration rubber is installed on the hub to ensure less vibration, low noise on the wheels and motors.
High efficiency coil
Coil are made of copper tubes and high exchange surface area aluminum blue fins. All coils are 100% tested against leaks by 16bar(1.6MPa) air pressure.
Condensate drain pan
In thermoforming high quality density expanded polystyrene, covered with a vacuum forming polyvinyl chloride, fitted with a condensates draining pump and a safety float.
Drain pump and float switch
850mm head drain pump with no return valve is installed in the unit; an float switch inside as well to prevent from leaking. If the water raising to a certainly position, the float switch will act and alarm, then the unit will cut off the water valve or stop the fan motor.
Optional
Wired wall controller, WIFI, RS485 ModBus, master-slave network control, 2-way valve, 3-way valve, electric heater
● 8-way cassette fan coil unit (AC motor, 2 pipes)
Remarks:
1. Cooling: inlet air temp. DB27 oC/WB19.5 oC, water inlet/outlet temp. 7 oC/12 oC.
2. Heating: inlet air temp. DB21 oC, water inlet temp. 60 oC; same water flow rate as for the cooling.
3. Sound pressure level is the test value of the unit running at high speed in an anechoic or semi anechoic chamber, 1 meter below and front of the unit.
● 8-way cassette fan coil unit (EC motor, 2 pipes)
Remarks:
1. Cooling: inlet air temp. DB27 oC/WB19.5 oC, water inlet/outlet temp. 7 oC/12 oC.
2. Heating: inlet air temp. DB21 oC, water inlet temp. 60 oC; same water flow rate as for the cooling.
3. Sound pressure level is the test value of the unit running at high speed in an anechoic or semi anechoic chamber, 1 meter below and front of the unit.
● 8-way cassette fan coil unit (AC motor, 4 pipes)
Remarks:
1. Cooling: inlet air temp. DB27 oC/WB19.5 oC, water inlet/outlet temp. 7 oC/12 oC.
2. Heating: inlet air temp. DB21 oC, water inlet temp. 60 oC; same water flow rate as for the cooling.
3. Sound pressure level is the test value of the unit running at high speed in an anechoic or semi anechoic chamber, 1 meter below and front of the unit.
● 8-way cassette fan coil unit (EC motor, 4 pipes)
Remarks:
1. Cooling: inlet air temp. DB27 oC/WB19.5 oC, water inlet/outlet temp. 7 oC/12 oC.
2. Heating: inlet air temp. DB21 oC, water inlet temp. 60 oC; same water flow rate as for the cooling.
3. Sound pressure level is the test value of the unit running at high speed in an anechoic or semi anechoic chamber, 1 meter below and front of the unit.
● 4-way cassette fan coil unit (AC motor, 2 pipes)
Remarks:
1. Cooling: inlet air temp. DB27 oC/WB19.5 oC, water inlet/outlet temp. 7 oC/12 oC.
2. Heating: inlet air temp. DB21 oC, water inlet temp. 60 oC; same water flow rate as for the cooling.
3. Sound pressure level is the test value of the unit running at high speed in an anechoic or semi anechoic chamber, 1 meter below and front of the unit.
● 4-way cassette fan coil unit (EC motor, 2 pipes)
Remarks:
1. Cooling: inlet air temp. DB27 oC/WB19.5 oC, water inlet/outlet temp. 7 oC/12 oC.
2. Heating: inlet air temp. DB21 oC, water inlet temp. 60 oC; same water flow rate as for the cooling.
3. Sound pressure level is the test value of the unit running at high speed in an anechoic or semi anechoic chamber, 1 meter below and front of the unit.
● 4-way cassette fan coil unit (AC motor, 4 pipes)
Remarks:
1. Cooling: inlet air temp. DB27 oC/WB19.5 oC, water inlet/outlet temp. 7 oC/12 oC.
2. Heating: inlet air temp. DB21 oC, water inlet temp. 60 oC; same water flow rate as for the cooling.
3. Sound pressure level is the test value of the unit running at high speed in an anechoic or semi anechoic chamber, 1 meter below and front of the unit.
● 4-way cassette fan coil unit (EC motor, 4 pipes)
Remarks:
1. Cooling: inlet air temp. DB27 oC/WB19.5 oC, water inlet/outlet temp. 7 oC/12 oC.
2. Heating: inlet air temp. DB21 oC, water inlet temp. 60 oC; same water flow rate as for the cooling.
3. Sound pressure level is the test value of the unit running at high speed in an anechoic or semi anechoic chamber, 1 meter below and front of the unit.
● 2-way cassette fan coil unit (AC motor, 2 pipes)
Remarks:
1. Cooling: inlet air temp. DB27 oC/WB19.5 oC, water inlet/outlet temp. 7 oC/12 oC.
2. Heating: inlet air temp. DB21 oC, water inlet temp. 60 oC; same water flow rate as for the cooling.
3. Sound pressure level is the test value of the unit running at high speed in an anechoic or semi anechoic chamber, 1 meter below and front of the unit.
● 2-way cassette fan coil unit (EC motor, 2 pipes)
Remarks:
1. Cooling: inlet air temp. DB27 oC/WB19.5 oC, water inlet/outlet temp. 7 oC/12 oC.
2. Heating: inlet air temp. DB21 oC, water inlet temp. 60 oC; same water flow rate as for the cooling.
3. Sound pressure level is the test value of the unit running at high speed in an anechoic or semi anechoic chamber, 1 meter below and front of the unit.