Home > Products > Terminal > Exposed Fan Coil Unit

Exposed Fan Coil Unit
Application areas
• Bureaux, business building, superstore, hotel, hospital, bank, apartment and amusement place.

Why this choice?
• Flexible installation: vertical or ceiling mounting
• Continuous air flow regulation and fan speed modulation
• Airfoil ABS wind wheel with high efficiency and U type bend pipe design
• Optional: wired wall controller, RS485 ModBus, master-slave network control, 2-way valve, 3-way valve, electric heater, with / without legs


Design features

Suitable for vertical or ceiling installation; inlet air grills is made of ABS; front air inlet or bottom air inlet (optional)


Air filter

Synthetic removable and washable


Heat exchanger

Copper tube and hydrophlic AL fins with air vent valve


Drain pan

L-shape, suitable for horizontal/vertical installation


Fan and motor

Centrifugal fan, EC motor


Optional

Wired wall controller, RS485 ModBus, master-slave network control, 2-way valve, 3-way valve, electric heater

Parameters

● Exposed fan coil unit (AC motor, 2 pipes 3 rows)

Exposed Fan Coil Unit

Remarks:
1. Cooling: inlet air temp. DB27 oC/WB19.5 oC, water inlet/outlet temp. 7 oC/12 oC.
2. Heating: inlet air temp. DB21 oC, water inlet temp. 60 oC; same water flow rate as for the cooling.
3. Sound pressure level is the test value of the unit running at high speed in an anechoic or semi anechoic chamber, 1 meter below and front of the unit.


● Exposed fan coil unit (EC motor, 2 pipes 3 rows)

Exposed Fan Coil Unit

Remarks:
1. Cooling: inlet air temp. DB27 oC/WB19.5 oC, water inlet/outlet temp. 7 oC/12 oC.
2. Heating: inlet air temp. DB21 oC, water inlet temp. 60 oC; same water flow rate as for the cooling.
3. Sound pressure level is the test value of the unit running at high speed in an anechoic or semi anechoic chamber, 1 meter below and front of the unit.


● Exposed fan coil unit (AC motor, 4 pipes 3+1 rows)

Exposed Fan Coil Unit

Remarks:

1. Cooling: inlet air temp. DB27 oC/WB19.5 oC, water inlet/outlet temp. 7 oC/12 oC.
2. Heating: inlet air temp. DB21 oC, water inlet temp. 60 oC; same water flow rate as for the cooling.
3. Sound pressure level is the test value of the unit running at high speed in an anechoic or semi anechoic chamber, 1 meter below and front of the unit.


● Exposed fan coil unit (EC motor, 4 pipes 3+1 rows)

Exposed Fan Coil Unit

Remarks:

1. Cooling: inlet air temp. DB27 oC/WB19.5 oC, water inlet/outlet temp. 7 oC/12 oC.
2. Heating: inlet air temp. DB21 oC, water inlet temp. 60 oC; same water flow rate as for the cooling.
3. Sound pressure level is the test value of the unit running at high speed in an anechoic or semi anechoic chamber, 1 meter below and front of the unit.

Catalog
Exposed Fan Coil Unit
Download